In line detonation flame arresters

G 20.6 N In-line detonation flame arrester, uni-directional, short-time burning proof

KITO® FD6-Det4-IIA-…-1.2 KITO® FD6-Det4-IIA-…-1.2-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Working unidirectional in pipes, whereby […]

G 20.6 N In-line detonation flame arrester, uni-directional, short-time burning proof Read More »

G 30 N Bi-directional in-line detonation flame arrester

KITO® FS-Det4-IIA-…-1.2 Installation into pipelines as inline detonation flame arrester e. g. for the protection of ignition gas lines or measuring devices. Applicable for all materials of the explosion groups IIA1 up to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Operating from both sides, for a maximum operating pressure of 1.2

G 30 N Bi-directional in-line detonation flame arrester Read More »

G 22.2 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® EFA-Det4-IIA-…/…-X10 KITO® EFA-Det4-IIA-…/…-X10-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experi-mental safe gap (MESG) > 0.9 mm. Bi-directionally working

G 22.2 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 22.1 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® CFA-Det4-IIA-…/…-1.2 KITO® CFA-Det4-IIA-…/…-1.2-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experi-mental safe gap (MESG) > 0.9 mm. Bi-directionally working

G 22.1 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 21 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® EFA-Det4-I-…/…-2.5 KITO® EFA-Det4-I-…/…-2.5-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion group IIA1 with a maximum experimental safe gap (MESG) ≥ 1.14 mm. Bi-directionally working in pipes,

G 21 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 20.3 N Uni-directional in-line detonation flame arrester, short-time burning proof

KITO® FD6-Det4-IIB1-…-1.2 KITO® FD6-Det4-IIB1-…-1.2-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB1 with a maximum experi-mental safe gap (MESG) ≥ 0.85 mm. Working unidirectional in pipes, whereby

G 20.3 N Uni-directional in-line detonation flame arrester, short-time burning proof Read More »

G 19.5 N Uni-directional in-line detonation flame arrester, short-time burning proof

KITO® FD4-Det4-IIB3-…-1.2 KITO® FD4-Det4-IIB3-…-1.2-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm. Working unidirectional in pipes, whereby

G 19.5 N Uni-directional in-line detonation flame arrester, short-time burning proof Read More »

G 19.4 N Uni-directional in-line detonation flame arrester, short-time burning proof

KITO® FD4-Det4-IIB-… KITO® FD4-Det4-IIB-…-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB with a maximum experimental safe gap (MESG) ≥ 0.5 mm. Working unidirectional in pipes, whereby

G 19.4 N Uni-directional in-line detonation flame arrester, short-time burning proof Read More »

G 19.3 N Uni-directional in-line detonation flame arrester, short-time burning proof

KITO® FD4-Det4-IIB1-…-1.2 KITO® FD4-Det4-IIB1-…-1.2-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB1 with a maximum experimental safe gap (MESG) ≥ 0.85 mm. Working unidirectional in pipes, whereby

G 19.3 N Uni-directional in-line detonation flame arrester, short-time burning proof Read More »

G 18.2 N Uni-directional in-line detonation flame arrester, short-time burning proof

KITO® FDN-Det4-IIB3-…-1.2 KITO® FDN-Det4-IIB3-…-1.2-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experi-mental safe gap (MESG) ≥ 0.65 mm. Working unidirectional in pipes, whereby

G 18.2 N Uni-directional in-line detonation flame arrester, short-time burning proof Read More »

Scroll to Top