In line armatures

F 37 N In-line pressure and vacuum relief valve

KITO® VD/T3-… As inline armature with venting and breathing function for application on fixed roof tanks and vessels. Equipped with a lateral Connection for the tank connecting pipe, a lower flange connection for a venting conduit and an upper flange connection for a breather conduit. The lower valve can be used to automatically control a […]

F 37 N In-line pressure and vacuum relief valve Read More »

F 37.1 N In-line pressure and vacuum relief valve

KITO® VD/T3-1-… As inline armature with venting and breathing function for application on fixed roof tanks and vessels. Equipped with a lateral Connection for the tank connecting pipe, a lower flange connection for a venting conduit and an upper flange connection for a breather conduit. The lower valve can be used to automatically control a

F 37.1 N In-line pressure and vacuum relief valve Read More »

F 18 N In-line pressure and vacuum relief valve

KITO® VD/o3-… Pressure compensation valve, preferably for inflammable liquids stored under inert gas, for venting and breathing of fixed roof tanks and above-ground tanks, with lateral connection for the inert gas conduit and a third outlet flange, e. g. for connection to a collecting conduit, for gas compensation or for combustion of exhaust air. The

F 18 N In-line pressure and vacuum relief valve Read More »

H 42 N Bi-directional in-line deflagration flame arrester, short-time burning proof

KITO® RG-Def-IIB3-…-1.2 KITO® RG-Def-IIB3-…-1.2-T (-TT) For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs.

H 42 N Bi-directional in-line deflagration flame arrester, short-time burning proof Read More »

H 42.0 N Bi-directional in-line deflagration flame arrester, short-time burning proof

KITO® RG-Def-IIB3-…-1.2 KITO® RG-Def-IIB3-…-1.2-T (-TT) – design with flange connection – For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm. Bi-directionally working in pipes, whereby an

H 42.0 N Bi-directional in-line deflagration flame arrester, short-time burning proof Read More »

H 41 N Bi-directional in-line deflagration flame arrester, short-time burning proof

KITO® RG-Def-IIA-…-1.2 KITO® RG-Def-IIA-…-1.2-T (-TT) For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs.

H 41 N Bi-directional in-line deflagration flame arrester, short-time burning proof Read More »

H 41.0 N Bi-directional in-line deflagration flame arrester, short-time burning proof

KITO® RG-Def-IIA-…-1.2 KITO® RG-Def-IIA-…-1.2-T (-TT) – design with flange connection – For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working in pipes, whereby an

H 41.0 N Bi-directional in-line deflagration flame arrester, short-time burning proof Read More »

H 40.2 N Bi-directional in-line deflagration flame arrester, endurance burning proof

KITO® RG-Def-I-…-1.3 KITO® RG-Def-I-…-1.3-T (-TT) -design with flange connection – For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion group IIA1 (old: I) with a maximum experimental safe gap (MESG) ≥ 1.14 mm. Bi-directionally working in pipes, whereby an operating

H 40.2 N Bi-directional in-line deflagration flame arrester, endurance burning proof Read More »

H 40.1 N Bi-directional in-line deflagration flame arrester, endurance burning proof

KITO® RG-Def-I-…-1.3 KITO® RG-Def-I-…-1.3-T (-TT) For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion group IIA1 (old: I) with a maximum experimental safe gap (MESG) ≥ 1.14 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.3 bar abs.

H 40.1 N Bi-directional in-line deflagration flame arrester, endurance burning proof Read More »

H 39 N Bi-directional in-line deflagration flame arrester, short-time burning proof

KITO® EFA-Def0-IIB3-…/…-1.2 KITO® EFA-Def0-IIB3-…/…-1.2-T (-TT) For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs.

H 39 N Bi-directional in-line deflagration flame arrester, short-time burning proof Read More »